10 resultados para SREBP-1c

em Universidad Politécnica de Madrid


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se ha caracterizado la infiltración de un suelo colocado en una columna de suelo de metacrilato, de base hexagonal de diagonal 1 m y 0,6 m de alto, con una densidad aparente de 1,5 g/cm3. El procedimiento utilizado ha sido la fibra óptica y el método denominado “Active Heating pulse method with Fiber Optic temperature sensing” AHFO method, que consiste en emitir un pulso óptico con láser y medir en el tiempo la señal reflejada, de baja intensidad, en diferentes puntos de la fibra óptica. Del espectro de luz reflejada solamente un rango de frecuencias específico, determinado por análisis de frecuencia, se correlaciona con la temperatura. La precisión en la medida es de ± 0,1ºC en una distancia de ± 12,5 cm. En el interior de la columna se colocó el cable de fibra óptica formando tres hélices concéntricas separadas 20 cm , 40 cm y 60 cm del centro. Asimismo, se cubrió la superficie del suelo con una altura media de agua que osciló entre 1,5 a 2,5 cm a lo largo de los 140 min que duró el proceso de calentamiento del cable. El incremento de temperatura antes y después del calentamiento se utilizó para determinar la infiltración instantánea a partir de la expresión de Perzlmaeir et al (2004) y de los números adimensional de Nusselt y Prandtl. Considerando los errores inherentes al procedimiento de cálculo, los resultados muestran que el AHFO method es una herramienta útil en el estudio de la variabilidad espacial de la infiltración en el suelo que permite, además, determinar su valor. Asimismo, muestra su potencial para incluir dichas estimaciones en la calibración de modelos relacionados con la gestión de recursos hídricos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

270 melocotones de la variedad Maycrest pertenecientes a 3 estados de madurez en recolección y almacenados 0, 1, 2, 3 y 4 semanas a 1°C y 5 °C, fueron ensayados mediante técnicas no destructivas (impacto no destructivo y espectroscopia en el infrarrojo cercano) con la finalidad de estimar la lanosidad (harinosidad en melocotón). Como referencia del grado de lanosidad de cada fruto se empleó procedimientos mecánicos destructivos (Magness-Taylor, compresión confinada y esfuerzo cortante). Los datos de impacto no destructivo se procesaron mediante análisis discriminante segregando los melocotones en 2 categorías de textura (crujientes, firmes y duros, y no crujientes, no firmes y blandos). De la misma manera, los melocotones fueron clasificados en 3 categorías de jugosidad de acuerdo con los valores de la segunda derivada de la curva de infrarrojo (de jugosidad alta, de jugosidad media y de jugosidad baja). Combinando los resultados de impacto e infrarrojo, la fruta no crujiente, no firme y blanda, clasificada como de jugosidad baja, fue identificada como lanosa. El porcentaje de bien clasificados es del 86,5%. Las conclusiones extraídas anteriormente por medio de ensayos destructivos, en relación con el efecto de los factores experimentales, han sido confirmadas con los procedimientos no destructivos aquí presentados: los melocotones lanosos aparecen principalmente a partir de las 2 semanas de almacenamiento a 5°C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, a novel method to trap and pattern ensembles of nanoparticles has been proposed and tested. It relies on the photovoltaic (PV) properties of certain ferroelectric crystals such as LiNbO3 [1,2]. These crystals, when suitably doped, develop very high electric fields in response to illumination with light of suitable wavelength. The PV effect lies in the asymmetrical excitation of electrons giving rise to PV currents and associated space-charge fields (photorefractive effect). The field generated in the bulk of the sample propagates to the surrounding medium as evanescent fields. When dielectric or metal nanoparticles are deposited on the surface of the sample the evanescent fields give rise to either electrophoretic or dielectrophoretic forces, depending on the charge state of the particles, that induce the trapping and patterning effects [3,4]. The purpose of this work has been to explore the effects of such PV fields in the biology and biomedical areas. A first work was able to show the necrotic effects induced by such fields on He-La tumour cells grown on the surface of an illuminated iron-doped LiNbO3 crystal [5]. In principle, it is conceived that LiNbO3 nanoparticles may be advantageously used for such biomedical purposes considering the possibility of such nanoparticles being incorporated into the cells. Previous experiments using microparticles have been performed [5] with similar results to those achieved with the substrate. Therefore, the purpose of this work has been to fabricate and characterize the LiNbO3 nanoparticles and assess their necrotic effects when they are incorporated on a culture of tumour cells. Two different preparation methods have been used: 1) mechanical grinding from crystals, and 2) bottom-up sol-gel chemical synthesis from metal-ethoxide precursors. This later method leads to a more uniform size distribution of smaller particles (down to around 50 nm). Fig. 1(a) and 1(b) shows SEM images of the nanoparticles obtained with both method. An ad hoc software taking into account the physical properties of the crystal, particullarly donor and aceptor concentrations has been developped in order to estimate the electric field generated in noparticles. In a first stage simulations of the electric current of nanoparticles, in a conductive media, due to the PV effect have been carried out by MonteCarlo simulations using the Kutharev 1-centre transport model equations [6] . Special attention has been paid to the dependence on particle size and [Fe2+]/[Fe3+]. First results on cubic particles shows large dispersion for small sizes due to the random number of donors and its effective concentration (Fig 2). The necrotic (toxicity) effect of nanoparticles incorporated into a tumour cell culture subjected to 30 min. illumination with a blue LED is shown in Fig.3. For each type of nanoparticle the percent of cell survival in dark and illumination conditions has been plot as a function of the particle dilution factor. Fig. 1a corresponds to mechanical grinding particles whereas 1b and 1c refer to chemically synthesized particles with two oxidation states. The light effect is larger with mechanical grinding nanoparticles, but dark toxicity is also higher. For chemically synthesized nanoparticles dark toxicity is low but only in oxidized samples, where the PV effect is known to be larger, the light effect is appreciable. These preliminary results demonstrate that Fe:LiNbO· nanoparticles have a biological damaging effect on cells, although there are many points that should be clarified and much space for PV nanoparticles optimization. In particular, it appears necessary to determine the fraction of nanoparticles that become incorporated into the cells and the possible existence of threshold size effects. This work has been supported by MINECO under grant MAT2011-28379-C03.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Navea, north of Spain, a medieval arch bridge shows a visible distortion (fig.1a). A stone falls down from the web of a gothic vault in a big parish church in Burgos (fig. 1b), and a voussoir falls down from the rib of another gothic vault in Oviedo (fig. 1c). An oval dome collapses in Zaragoza, though another four identical domes remain safe (fig. 1d). Sometimes the building has to support new, heavier loads. The ruin of the abandoned (since the 19th Century) monastery of Melón should be consolidated, some vaults are rebuilt and the visitors can walk over them. A Franciscan Convent is going to be turned into a Cultural Centre, the loads to be supported being multiplied by a factor of two. A little medieval bridge is asked to support the pass of heavy lorries. These are some of the cases I have studied in the last two decades, all of them referring to questions of structural safety. These are the kind of situations which often occurs in the field of Historic Structures. They require a study and an answer. This is no scholarly work (though in some cases new lines of future research will emerge). A judgement must be made by the expert and this judgement affects the safety and economy, in the last instance, of people. As there are rarely unique answers, the behaviour of the expert, then, can also be judged as "ethical", if he proposes an intervention that is necessary and adequate (or, recommends no intervention, judging the situation safe), or "non-ethical", if recommends an unnecessary or disproportionate intervention. In relation to the monument, also, the proposal can be judged ethically; any intervention damaging seriously the character of the monument may be labelled un-ethical.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La infiltración de agua en el suelo y la recarga profunda del agua subterránea contenida en los acuíferos es un proceso lento en relación con otros fenómenos hidrológicos. La redacción de esta tesis ha pretendido contribuir al estudio de la influencia que el almacenamiento de la precipitación sólida en forma de manto de nieve y su eventual fusión puedan tener sobre dicho proceso en áreas de media montaña (1.000 – 2.000 m.) en las que con gran frecuencia se sitúan las cabeceras de los ríos peninsulares. Para ello se ha partido del análisis de las diferentes variables intervinientes durante un determinado periodo temporal y sobre un espacio geográfico concreto, por lo que su metodología es de naturaleza empírica. La extensión del periodo (2002/03 a 2010/11) ha venido condicionada por la disponibilidad de los valores de algunas de sus principales variables, como han sido el equivalente en agua de la nieve acumulada y los caudales procedentes de su fusión. Éstos se han obtenido como resultado de la aplicación del modelo ASTER, desarrollado en el programa de Evaluación de los Recursos Hídricos procedentes de la Innivación (ERHIN), calibrado – entre otros- con datos de precipitaciones, temperatura y caudales provenientes a su vez del Sistema Automático de Información Hidrológica (SAIH). Ambos programas fueron implantados por la Administración en las diferentes Confederaciones Hidrográficas y en determinados Organismos de cuenca actuales, en cuyo desarrollo participó el autor de esta tesis. En cuanto a la zona de estudio se ha procedido a su elección considerando las posibles áreas de media montaña en las que la presencia de la nieve fuera hidrológicamente significativa y estuvieran constituidas litológicamente por afloramientos permeables que no impidieran la infiltración en el terreno y la formación de acuíferos de cierta relevancia. El interés se centró discrecionalmente en la cuenca del Tajo, tanto por el carácter estratégico de la misma -como suministradora en la actualidad de excedentes a otras cuencas deficitarias- como por el valor representativo de sus condiciones climáticas y orográficas en relación con otras cuencas hidrográficas peninsulares. Para ello se partió de las cabeceras de ríos identificadas por el programa ERHIN por su interés nivológico para la implantación del modelo ASTER y de las Masas de Agua Subterráneas MASb (antes Unidades Hidrogeológicas UUHH) definidas en los planes hidrológicos. La intersección en el territorio de ambos criterios condujo, finalmente, a la zona del Alto Tajo, en la que se cumplen ambos requisitos. El tramo quedó concretado en el comprendido entre las cabeceras de los ríos Tajo y Guadiela y la cola de los embalses de Entrepeñas y Buendía respectivamente, puntos de cierre para la calibración llevada a cabo en la modelización ASTER. Gran parte de éste discurre, en su parte alta, sobre rocas carbonatadas (calizas y dolomías del Jurásico y Cretácico), relacionados con las MASb de Tajuña-Montes Universales, Molina de Aragón y Sigüenza-Maranchón. Los valores diarios de las reservas de agua en forma de nieve, evapotranspiración y caudales procedentes de la fusión se han obtenido a partir de los resultados del mencionado modelo, procediéndose al cálculo de la infiltración por balance hídrico durante el periodo de estudio considerado, teniendo en cuenta los valores de precipitación, evapotranspiración y aportaciones de caudales. Esto ha requerido el estudio previo de las condiciones hidrogeológicas de la zona seleccionada con objeto de conocer las posibles interconexiones subterráneas que pudieran alterar los saldos entre las variables intervinientes anteriormente citadas. Para ello se ha llevado a cabo la recopilación y análisis de la información hidrogeológica correspondiente a la documentación de los planes hidrológicos del Tajo (Plan Hidrológico de la cuenca del Tajo RD 1664/1998 y el actual Plan Hidrológico de la parte española de la Demarcación Hidrográfica del Tajo RD 270/2014) y de los estudios previos realizados por el organismo de cuenca y el Instituto Geológico y Minero de España (lGME) fundamentalmente. En relación con la MASb Tajuña-Montes Universales -cuya extensión supera la zona seleccionada- dichos estudios consideran su estructura geológica y distribución litológica, con intercalaciones impermeables que actúan como barreras, dividiendo a éstas en Subunidades e identificando las zonas de drenaje de sus respectivos acuíferos. También se ha considerado la documentación y estudios previos del Plan Hidrológico Nacional sobre las Unidades Hidrogeológicas compartidas entre ámbitos geográficos de diferentes planes hidrológicos. Se concluye que las divisorias hidrográficas de las cabeceras son sensiblemente coincidentes o abarcan las Subunidades Montes Universales meridionales, Priego, Cifuentes, Zaorejas, u Montes Universales septentrionales, que drenan hacia el Tajo/Guadiela (bien directamente, bien a través de afluentes como el Gallo, Ablanquejo, Cabrillas, Cuervo…), MASb Molina de Aragón, que drena al Tajo a través del río Gallo y MASb Sigüenza—Maranchón, que drena su parte correspondiente hacia el Tajo a través del Ablanquejo. Se descartan – salvo la pequeña salvedad del manantial de Cifuentes- las conexiones hidrogeológicas con otras MASb o Subunidades por lo que las cabeceras del Tajo y del Guadiela pueden considerarse como un Sistema independiente donde las precipitaciones no evaporadas escurren superficialmente o se infiltran y descargan hacia los embalses de Entrepeñas y Buendía. La cuantificación diaria y acumulada de los balances hídricos ha permitido calcular la evolución aproximada de las reservas de agua subterránea desde la fecha inicial. Originalmente los balances se realizaron de forma separada en las cabeceras del Tajo y del Guadiela, cuyos valores acumulados manifestaron una tendencia creciente en la primera y decreciente en la segunda. Dicha situación se equilibra cuando el balance se practica conjuntamente en ambas, apreciándose en la variación del volumen de agua subterránea una evolución acorde hidrológicamente con los ciclos de verano/invierno y periodos de sequía, manteniéndose sus valores medios a largo/medio plazo, poniendo en evidencia la existencia de interconexiones subterráneas entre ambas cuencas. El balance conjunto, agregando la cabecera del Tajuña (que también comparte los materiales permeables de la MASb Tajuña-Montes Universales) no reveló la existencia de nuevas interrelaciones hidrogeológicas que influyeran en los balances hídricos realizados Tajo/Guadiela, confirmando las conclusiones de los estudios hidrogeológicos anteriormente analizados. Se ha procedido a confrontar y validar los resultados obtenidos de la evolución de las reservas de agua subterránea mediante los siguientes procedimientos alternativos: - Cálculo de los parámetros de desagüe de la curva de agotamiento correspondiente al volumen de agua subterránea drenante hacia el Tajo/Guadiela. Éste se ha realizado a partir de las aportaciones mensuales entrantes en los embalses de Entrepeñas y Buendía durante los meses de junio, julio, agosto y septiembre, cuyos valores responden al perfil típico de descargas de un acuífero. A partir de éstos se ha determinado el volumen drenante correspondiente al primero de junio de cada año de la serie histórica considerada. - Determinación del caudal base por el método Wallingford y deducción de los volúmenes drenantes. Estimación de las recarga anuales - Cuantificación de la recarga anual por el método Sanz, Menéndez Pidal de Navascués y Távara. Se obtuvieron valores de recarga muy aproximados entre los calculados por los dos últimos procedimientos citados. Respecto a las reservas de agua subterránea almacenadas siguen una evolución semejante en todos los casos, lo que ha permitido considerar válidos los resultados conseguidos mediante balance hídrico. Confirmada su solidez, se han buscado correlaciones simples entre el volumen de las reservas subterráneas (como indicador estimativo del efecto de la infiltración) y los volúmenes procedentes de la fusión. La conclusión es que estos últimos no tienen un efecto determinante a escala anual sobre la infiltración,recarga y variación de los volúmenes de agua subterránea, frente al peso de otras variables (precipitación y evapotranspiración). No obstante se ha encontrado una buena correlación múltiple entre la recarga estimada y la precipitación eficaz (precipitación menos evapotranspiración) y fusión, que ha permitido cuantificar la contribución de esta última. Posteriormente se ha recurrido a la selección de los episodios más intensos de acumulación /fusión en las cabeceras del Tajo y Guadiela. Y se procedió a la comparación entre los resultados obtenidos por aplicación del modelo de simulación en los mismos periodos (normalmente de varios días de duración) con datos reales y con datos ficticios de temperatura que anularan o disminuyeran la presencia de nieve, apreciándose una gran sensibilidad del efecto de la temperatura sobre la evapotranspiración y estableciéndose nuevamente correlaciones lineales entre los volúmenes de fusión y el incremento de reservas subterráneas. Las mismas confirman el efecto “favorecedor” de la acumulación de agua en forma de nieve y su posterior licuación, sobre sobre la infiltración de agua en el suelo y almacenamiento subterráneo. Finalmente se establecieron varios escenarios climáticos (+1ºC; +3ºC; +1ºC y – 10% precipitación; y 3ºC – 10% precipitación) compatibles con las previsiones del IPCC para mediados y finales del presente siglo, determinándose mediante simulación ASTER los correspondientes valores de fusión. La correlación establecida a escala anual ha permitido evaluar el efecto de la disminución del volumen de fusión - en los diferentes escenarios – sobre la recarga, pronosticando un descenso de los caudales de estiaje y la desaparición del “efecto nieve” sobre la infiltración y recarga con un aumento de 3ºC de temperatura. Teniendo en cuenta las condiciones de representatividad de la zona elegida, resulta verosímil la extensión de las anteriores conclusiones a otras cabeceras fluviales enclavadas en áreas de media montaña situadas entre 1000 a 2000m y sus efectos aguas abajo.Water infiltration into the soil and groundwater recharge deep water in aquifers is slow relative to other hydrological phenomena. The wording of this thesis aims to contribute to the study of the influence that the storage of solid precipitation as snow cover and its eventual melting may have on this process in mid-mountain areas (1000 - 2,000 m) where very often the headwaters of the peninsular rivers are located. For this party analysis of the different variables involved has over a given time period and a particular geographical area, so that their methodology is empirical in nature. The extension of the period (2002/03 to 2010/11) has been conditioned by the availability of the values of some of its key variables, as were the water equivalent of the snow and flows from melting. These have been obtained as a result of the application of ASTER model, developed in the program Evaluation of Water Resources from the Innivation (ERHIN), calibrated - among others data of rainfall, temperature and flow from turn System Automatic Hydrological Information (SAIH). Both programs were implemented by the Administration in the different Water Boards and to undertakings for current basin, in which the author participated development of this thesis. As for the study area has proceeded at its option considering the possible areas of midmountain in the presence of snow outside hydrological meaningful and they were lithology consisting of permeable outcrops that did not prevent infiltration into the ground and forming aquifers of some significance. We were interested discretion in the Tagus basin, therefore the strategic nature of it, as currently supplying surplus to other basins deficit- as the representative value of its climate and terrain conditions in relation to other peninsular river basins . To do this we started from the headwaters identified by the ERHIN program for its implementation snow interest to the ASTER model and Ground Water Bodies MASb (before UUHH Hydrogeological Units) defined in hydrological plans. The intersection in the territory of both criteria led eventually to the Alto Tajo, in which both requirements are met. The section was finalized in the period between the headwaters of the Tagus and Guadiela rivers and reservoirs end Entrepeñas and Buendia respectively checking points for calibration performed in ASTER modeling. Much of it runs on carbonate rocks (limestones and dolomites of Jurassic and Cretaceous) related MASb of Tajuña -Montes Universal, Molina de Aragón and Sigüenza-Maranchón. The daily values of water reserves in the form of snow, evapotranspiration and flow from melting were obtained from the results of this model, proceeding to the calculation of infiltration water balance during the study period considered, taking into account values of precipitation, evapotranspiration and input flow. This has required the prior examination of the hydrogeological conditions of your required in order to know the possible underground interconnections that could alter the balance between the intervening variables aforementioned area. For this we have carried out the collection and analysis of hydrogeological information relevant documentation Tagus river management plans (Hydrological Plan Tajo Basin RD 1664/1998 and the current Hydrological Plan of the Spanish part of the River Basin Tagus RD 270/2014) and previous studies by the basin organization and the Geological Survey of Spain (IGME) mainly. Regarding the MASb Tajuña- Montes Universal - whose length exceeds the area selected - these studies consider its geological structure and lithology distribution with waterproof collations that act as barriers, dividing it into subunits and identifying areas draining their respective aquifers. It has also considered the documentation and previous studies of the National Hydrological Plan on shared among different geographical areas management plans Hydrogeological Units. We conclude that river dividing the headers are substantially coincident or covering Subunits southern Universal Montes, Priego Cifuentes, Zaorejas and northern Universal Mounts, which drain into the Tagus / Guadiela (either directly or through tributaries such as Gallo, Ablanquejo , whitecaps , Raven ...), MASb Molina de Aragón which drains through the Tajo del Gallo and MASb Sigüenza- Maranchón river that drains into the Tagus using the Ablanquejo . Discarded - except the small exception of spring Cifuentes -hydrogeological connections with other MASb or Subunits so the headwaters of the Tagus and Guadiela be considered as a separate system, where rainfall not evaporated runs on surface or infiltrates and eventually discharged into reservoirs Entrepeñas and Buendia. The daily and cumulative quantification of water balances allowed us to compute the approximate evolution of groundwater reserves from its initial date. Initially balances were performed separately in the headwaters of the Tagus and Guadiela, whose cumulative values showed an increasing trend in the first and decreasing in the second. This situation is balanced when the balance is practiced together in both , appreciating the change in volume of groundwater hydrological evolution commensurate with the cycles of summer / winter and drought periods , keeping their average long / medium term values and putting in shows the existence of underground interconnections between the two basins. The overall balance, adding header Tajuña (which also shares the permeable materials MASb Tajuña -Montes Universal ) did not reveal the existence of new hydrogeological interrelationships that influenced water balances made Tajo / Guadiela, confirming the findings of the hydrogeological studies previously analyzed. We proceeded to confront and validate the results of the evolution of groundwater reserves by the following alternative procedures: - Calculate the parameters drain depletion curve corresponding to the volume of groundwater draining into the Tajo / Guadiela. This has been made from monthly inflows in the reservoirs of Entrepeñas and Buendia during the months of June, July, August and September, whose values match the typical profile of an aquifer discharges. From these has been determined for the first of June each year of the time series considered drainage volume - Determination of base flow by Wallingford method and deduction of drainage volumes. Estimate of annual recharge - Quantification of the annual recharge by the method Sanz Menéndez Pidal of Navascués and Távara. Very approximate values recharge between calculated for the last two mentioned methods were obtained. Concerning groundwater reserves stored follow a similar pattern in all cases, allowing consider valid the results achieved through water balance. Confirmed its robustness, simple correlations were sought between the volume of groundwater reserves (as estimated indicator of the effect of infiltration) and volumes from the melting. The conclusion is that the latter do not have a decisive effect on the annual scale infiltration, recharge and variation in volumes of groundwater, against the weight of other variables (precipitation and evapotranspiration). However found a good multiple correlation between the estimated recharge and effective precipitation (precipitation minus evapotranspiration) and fusion, which allowed quantify the contribution of the latter. Subsequently it has resorted to the selection of the most intense episodes of accumulation / melting in the headwaters of the Tagus and Guadiela. And we proceeded to the comparison between the results obtained by application of the simulation model in the same periods (usually several days) with real data and fictitious temperature data to annul or decrease the presence of snow, appreciating a great sensitivity of the effect of temperature on evapotranspiration and establishing linear correlations between the volumes of melting and increased groundwater reserves again. They confirm the “flattering " effect of water accumulation as snow and subsequent liquefaction of the infiltration of water into the soil and underground storage. Finally various climate scenarios (+1ºC; +3ºC; +1ºC y – 10% precipitation; y 3ºC – 10% precipitation) were established consistent with IPCC projections for mid - to late - century, determined through simulation ASTER corresponding values of melting. The correlation established on an annual scale has allowed to evaluate the effect of decreasing the volume of melt - in different scenarios - on recharge, predicting a decline in low flows and the disappearance of "snow effect" on infiltration and recharge with an increase of 3°C temperature. Given the conditions of representativeness of the chosen area, plausible extension of the above findings to other landlocked headwaters in mid-mountain areas located between 1000 to 2000m and its downstream effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper addresses the determination of the realized thermal niche and the effects of climate change on the range distribution of two brown trout populations inhabiting two streams in the Duero River basin (Iberian Peninsula) at the edge of the natural distribution area of this species. For reaching these goals, new methodological developments were applied to improve reliability of forecasts. Water temperature data were collected using 11 thermographs located along the altitudinal gradient, and they were used to model the relationship between stream temperature and air temperature along the river continuum. Trout abundance was studied using electrofishing at 37 sites to determine the current distribution. The RCP4.5 and RCP8.5 change scenarios adopted by the International Panel of Climate Change for its Fifth Assessment Report were used for simulations and local downscaling in this study. We found more reliable results using the daily mean stream temperature than maximum daily temperature and their respective seven days moving-average to determine the distribution thresholds. Thereby, the observed limits of the summer distribution of brown trout were linked to thresholds between 18.1ºC and 18.7ºC. These temperatures characterise a realised thermal niche narrower than the physiological thermal range. In the most unfavourable climate change scenario, the thermal habitat loss of brown trout increased to 38% (Cega stream) and 11% (Pirón stream) in the upstream direction at the end of the century; however, at the Cega stream, the range reduction could reach 56% due to the effect of a ?warm-window? opening in the piedmont reach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of the temperature gradients in cold stores and containers is a critical issue in the food industry for the quality assurance of products during transport and for minimising losses. This work presents an analysis of the temperatures during the refrigerated transport of 4,320 kg of blueberries in a reefer (set point temperature at ?1ºC) on a container ship from Montevideo (Uruguay) to Verona (Italy). The monitoring was performed by using semi-passive RFID loggers (TurboTag cards). The objective was to carry out a multi-distributed supervision using low-cost, wireless and autonomous sensors for the characterisation of the distribution and spatial gradients of temperatures during a long distance transport. Data analysis shows spatial (phase space) and temporal sequencing diagrams and reveals a significant heterogeneity of temperature at different locations in the container, which highlights the ineffectiveness of a temperature control system based on a single sensor, as is usually done.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La perdiz roja es la especie cinegética por excelencia en la península ibérica, cuya cría en cautividad y suelta controlada comenzó a regularse en los años 70 con la aparición del ICONA. La incubación controlada de huevos de perdiz es imprescindible, con fines cinegéticos y de preservación de la especie, y se desarrolla con incubadoras comerciales de pequeña y mediana escala, distribuidas en zonas rurales con acceso limitado y/o deficiente al suministro eléctrico. En nuestras latitudes el aporte de energía solar térmica se perfila como una posibilidad de mejorar la eficiencia energética de éstas y otras instalaciones y de reducir la dependencia energética exterior. Hay diversos factores físico-químicos que influyen en la calidad de la incubación: temperatura, humedad relativa, y concentración de gases, de los cuales sólo los dos primeros son habitualmente supervisados y controlados en este tipo de incubadoras. Esta Tesis surge en el marco de dos proyectos de cooperación con la AECID, y tiene como objetivos: la caracterización espacial de variables relevantes (temperatura (T), humedad relativa (HR)) en la incubadora comercial durante el proceso de incubación, la determinación de la relación existente entre la evolución de variables ambientales durante el proceso de incubación y la tasa de nacimientos (35-77%), así como el diseño y evaluación del sistema de apoyo solar térmico para determinar su potencial de utilización durante las incubaciones comerciales. La instalación de un número limitado de sensores permite la monitorización precisa del proceso de incubación de los huevos. Los resultados más relevantes indican que en incubaciones comerciales los gradientes de T y HR han sido despreciables (1ºC de diferencia entre las posiciones con mayor y menor T media y un 4,5% de diferencia entre las posiciones con mayor y menor HR), mientras que el seguimiento y ajuste (mediante modelos de crecimiento) de la concentración de CO2 (r2 entre 0,948 y 0,987 en las 5 incubaciones, para un total de 43315 huevos) permite valorar la actividad fisiológica de los huevos e incluso predecir la tasa de éxito (nacimientos), basándose en la concentración de CO2 estimada mediante modelos de crecimiento en el día 20 de incubación (r2 entre 0,997 y 0,994 según el modelo de estimación empleado). El sistema ha sido valorado muy positivamente por los productores (Finca Cinegética Dehesa Vieja de Galapagar). El aporte térmico se ha diseñado (con mínima intrusión en el sistema comercial) sobre la base de un sistema de enfriamiento de emergencia original de la incubadora, al que se han incorporado un colector solar, un depósito, un sistema de electroválvulas, una bomba de circulación y sensores de T en distintos puntos del sistema, y cuyo control ha sido automatizado. En esta Tesis se muestra que la contribución solar puede aportar hasta un 42% de las demandas de energía en nuestras condiciones geográficas para una temperatura de consigna dentro de la incubadora de 36.8ºC, sin afectar a la estabilidad de la temperatura. Además, el rendimiento del colector solar se ha acotado entre un 44% y un 85%, de acuerdo con los cálculos termodinámicos; valores que se mantienen dentro del rango aportado por el fabricante (61%). En el futuro se plantea evaluar el efecto de distintas estrategias de control, tales como controladores difusos, que incorporan el conocimiento experto al control automático. ABSTRACT The partridge is the quintessential game species in the Iberian Peninsula, which controlled breeding and release, began to be regulated in the 70s with the emergence of ICONA. The controlled incubation of eggs is essential, and takes place in commercial incubators of small and medium scale, distributed in rural areas with limited and/or inadequate access to power. In our latitudes the contribution of solar thermal energy is emerging as a possibility to improve the energy efficiency of the facilities and to reduce external energy dependence. There are various physicochemical factors influencing the quality of incubation: temperature, relative humidity and concentration of gases, of which only the first two are typically monitored and controlled in such incubators. This PhD comes within the framework of two cooperation projects with AECID and aims: the spatial characterization of relevant variables in a commercial incubator (temperature (T), and relative humidity (HR)), determining the relationships in the changes in environmental variables during incubation and birth rates (35-77%) as well as the design and evaluation of solar thermal support system to determine its potential use during commercial incubations; the installation of a limited number of sensors has allowed accurate monitoring of incubation of eggs. The most relevant results indicate that in commercial incubations, the gradients in T and HR have been negligible (1°C difference between the highest and lowest positions T and average 4.5% difference between the highest and lowest positions HR), while monitoring and fit using growth models of the concentration of CO2 (r2 between 0.948 and 0.987 in 5 incubations, for a total amount of 43,315 eggs) allows assessing the physiological activity of the eggs and even predict the success rate (hatchability), based on the estimated concentration of CO2 by using growth models on day 20 of incubation (r2 between 0.997 and 0.994 depending on the fit model).The system has been highly valued by producers (Finca Cinegética Dehesa Vieja de Galapagar). The hybrid heat system is designed (with minimal intrusion into the commercial system) based on an emergency cooling device, original in the incubator. New elements have been incorporated: a solar collector, a tank, a system of solenoid valves, a circulating pump and T sensors at various points of the system, whose control has been automated. This PhD shows that the solar contribution is responsible for up to 42% of energy demands in our geographical conditions for a setpoint temperature inside the incubator of 36.8ºC, without questioning the stability of the temperature. Furthermore, the efficiency of the solar collector has been bounded between 44% and 85%, according to thermodynamic calculations; values remain within the range provided by the manufacturer (61%). In the future it is proposed to evaluate the effect of different control strategies, such as fuzzy controllers, which incorporate the expertise to automated control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tesis doctoral presenta el desarrollo, verificación y aplicación de un método original de regionalización estadística para generar escenarios locales de clima futuro de temperatura y precipitación diarias, que combina dos pasos. El primer paso es un método de análogos: los "n" días cuya configuración atmosférica de baja resolución es más parecida a la del día problema, se seleccionan de un banco de datos de referencia del pasado. En el segundo paso, se realiza un análisis de regresión múltiple sobre los "n" días más análogos para la temperatura, mientras que para la precipitación se utiliza la distribución de probabilidad de esos "n" días análogos para obtener la estima de precipitación. La verificación de este método se ha llevado a cabo para la España peninsular y las Islas Baleares. Los resultados muestran unas buenas prestaciones para temperatura (BIAS cerca de 0.1ºC y media de errores absolutos alrededor de 1.9ºC); y unas prestaciones aceptables para la precipitación (BIAS razonablemente bajo con una media de -18%; error medio absoluto menor que para una simulación de referencia (la persistencia); y una distribución de probabilidad simulada similar a la observada según dos test no-paramétricos de similitud). Para mostrar la aplicabilidad de la metodología desarrollada, se ha aplicado en detalle en un caso de estudio. El método se aplicó a cuatro modelos climáticos bajo diferentes escenarios futuros de emisiones de gases de efecto invernadero, para la región de Aragón, produciendo así proyecciones futuras de precipitación y temperaturas máximas y mínimas diarias. La fiabilidad de la técnica de regionalización fue evaluada de nuevo para el caso de estudio mediante un proceso de verificación. Para determinar la capacidad de los modelos climáticos para simular el clima real, sus simulaciones del pasado (la denominada salida 20C3M) se regionalizaron y luego se compararon con el clima observado (los resultados son bastante robustos para la temperatura y menos concluyentes para la precipitación). Las proyecciones futuras a escala local presentan un aumento significativo durante todo el siglo XXI de las temperaturas máximas y mínimas para todos los futuros escenarios de emisiones considerados. Las simulaciones de precipitación presentan mayores incertidumbres. Además, la aplicabilidad práctica del método se demostró también mediante su utilización para producir escenarios climáticos futuros para otros casos de estudio en los distintos sectores y regiones del mundo. Se ha prestado especial atención a una aplicación en Centroamérica, una región que ya está sufriendo importantes impactos del cambio climático y que tiene un clima muy diferente. ABSTRACT This doctoral thesis presents the development, verification and application of an original downscaling method for daily temperature and precipitation, which combines two statistical approaches. The first step is an analogue approach: the “n” days most similar to the day to be downscaled are selected. In the second step, a multiple regression analysis using the “n” most analogous days is performed for temperature, whereas for precipitation the probability distribution of the “n” analogous days is used to obtain the amount of precipitation. Verification of this method has been carried out for the Spanish Iberian Peninsula and the Balearic Islands. Results show good performance for temperature (BIAS close to 0.1ºC and Mean Absolute Errors around 1.9ºC); and an acceptable skill for precipitation (reasonably low BIAS with a mean of - 18%, Mean Absolute Error lower than for a reference simulation, i.e. persistence, and a well-simulated probability distribution according to two non-parametric tests of similarity). To show the applicability of the method, a study case has been analyzed. The method was applied to four climate models under different future emission scenarios for the region of Aragón, thus producing future projections of daily precipitation and maximum and minimum temperatures. The reliability of the downscaling technique was re-assessed for the study case by a verification process. To determine the ability of the climate models to simulate the real climate, their simulations of the past (the 20C3M output) were downscaled and then compared with the observed climate – the results are quite robust for temperature and less conclusive for the precipitation. The downscaled future projections exhibit a significant increase during the entire 21st century of the maximum and minimum temperatures for all the considered future emission scenarios. Precipitation simulations exhibit greater uncertainties. Furthermore, the practical applicability of the method was demonstrated also by using it to produce future climate scenarios for some other study cases in different sectors and regions of the world. Special attention was paid to an application of the method in Central America, a region that is already suffering from significant climate change impacts and that has a very different climate from others where the method was previously applied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.